We use cookies and other tools to enhance your experience on our website and to analyze our web traffic.
For more information about these cookies and the data collected, please refer to our Privacy Policy.

Sleep Heart Health Study

Name Label Folder
ai_rem
Arousal Index (REM): Arousals per hour of REM sleep from type II polysomnography
Arousal Index (REM): Arousals per hour of REM sleep from type II polysomnography Sleep Monitoring/Polysomnography/Arousals
arnrembp
Total number of arousals during NREM sleep in supine position from type II polysomnography
Total number of arousals during NREM sleep in supine position from type II polysomnography Sleep Monitoring/Polysomnography/Arousals
arnremop
Total number of arousals during NREM sleep in non-supine position from type II polysomnography
Total number of arousals during NREM sleep in non-supine position from type II polysomnography Sleep Monitoring/Polysomnography/Arousals
arrembp
Total number of arousals during REM sleep in supine position from type II polysomnography
Total number of arousals during REM sleep in supine position from type II polysomnography Sleep Monitoring/Polysomnography/Arousals
arremop
Total number of arousals during REM sleep in non-supine position from type II polysomnography
Total number of arousals during REM sleep in non-supine position from type II polysomnography Sleep Monitoring/Polysomnography/Arousals
alpha_intrusion_pct_3sepochs
Alpha intrusion (% of 3-s epochs)
Alpha intrusion (% of 3-s epochs)

Percent of 3-sec epochs with alpha power >30mV2

Younes et al. 2021 (PubMed ID: 34156473)

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
avg_normalized_eeg_power
Average Normalized EEG Power
Average Normalized EEG Power

In some PSGs the EEG is generally low in amplitude in all frequency ranges while in others it is high. The reasons for these differences could be technical (distance between active and reference electrode, electrode impedance), biological (e.g. age, skin or skull impedance) or some other reason Younes et al. 2021 (PubMed ID: 34156473).

This index was recently found to be a risk factor for future development of dementia (Stone et al. 2018). In addition, it was found to be highly reproducible across 5 years of follow up. A high value also results in artifactually high spindle power and density and higher alpha intrusion.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
avg_org_trt
Average ORP Over Total Recording Time
Average ORP Over Total Recording Time

Average Odds Ratio Product (ORP) in all 30-s epochs during total recording time.

ORP is a continuous index of sleep depth and wake propensity. A value of 0 indicates very deep sleep, a value of 2.5 indicates full wakefulness.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
avg_orp_last120m_nrem
Avg ORP Last 120 min NREM
Avg ORP Last 120 min NREM

Used (along with min_orp_firsthalf_nrem) to calculate diff_orp.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
avg_orp_n1
Average ORP During N1
Average ORP During N1

Average Odds Ratio Product (ORP) in all 30-s epochs during manually scored sleep stages.

ORP is a continuous index of sleep depth and wake propensity. A value of 0 indicates very deep sleep, a value of 2.5 indicates full wakefulness.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
avg_orp_n2
Average ORP During N2
Average ORP During N2

Average Odds Ratio Product (ORP) in all 30-s epochs during manually scored sleep stages.

ORP is a continuous index of sleep depth and wake propensity. A value of 0 indicates very deep sleep, a value of 2.5 indicates full wakefulness.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
avg_orp_n3
Average ORP During N3
Average ORP During N3

Average Odds Ratio Product (ORP) in all 30-s epochs during manually scored sleep stages.

ORP is a continuous index of sleep depth and wake propensity. A value of 0 indicates very deep sleep, a value of 2.5 indicates full wakefulness.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
avg_orp_nonrem
Average ORP During non-REM
Average ORP During non-REM

Average Odds Ratio Product (ORP) in all 30-s epochs during manually scored sleep stages.

ORP is a continuous index of sleep depth and wake propensity. A value of 0 indicates very deep sleep, a value of 2.5 indicates full wakefulness.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
avg_orp_rem
Average ORP During REM
Average ORP During REM

Average Odds Ratio Product (ORP) in all 30-s epochs during manually scored sleep stages.

ORP is a continuous index of sleep depth and wake propensity. A value of 0 indicates very deep sleep, a value of 2.5 indicates full wakefulness.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
avg_orp_wake
Average ORP During Wake
Average ORP During Wake

Average Odds Ratio Product (ORP) in all 30-s epochs during manually scored sleep stages.

ORP is a continuous index of sleep depth and wake propensity. A value of 0 indicates very deep sleep, a value of 2.5 indicates full wakefulness.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
baseline_hr
Arousal Characteristics - Baseline HR
Arousal Characteristics - Baseline HR

Heart rate in repsonse to arousals.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
change_in_hr_perh_trt
Arousal Characteristics - Change in HR per hr of TRT
Arousal Characteristics - Change in HR per hr of TRT

Heart rate in repsonse to arousals.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
clinical_category
Clinical Category
Clinical Category

Clinical Category as per Younes et al. 2021 (PubMed ID: 34156473)

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
delta_hr
Arousal Characteristics - Delta HR
Arousal Characteristics - Delta HR

Heart rate in repsonse to arousals.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
dhr_intensity
Arousal Characteristics - dHR/ Intensity
Arousal Characteristics - dHR/ Intensity

Heart rate in repsonse to arousals.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
diff_orp
Change in ORP across the night
Change in ORP across the night

Change in Odds Ratio Product (ORP) across the night, a greater increase in ORP from the beginning of to end of the night suggests more restorative sleep. Younes et al. 2020 (PubMed ID: 32729619).

Source: avg_orp_last120m_nrem and min_orp_firsthalf_nrem.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
icc_ms_cols
Breakdown of ICC components - MS Columns
Breakdown of ICC components - MS Columns

Component of intraclass correlation, see icc_rl_orp for more information.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
icc_ms_error
Breakdown of ICC components - MS Error
Breakdown of ICC components - MS Error

Component of intraclass correlation, see icc_rl_orp for more information.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
icc_ms_rows
Breakdown of ICC components - MS Rows
Breakdown of ICC components - MS Rows

Component of intraclass correlation, see icc_rl_orp for more information.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
icc_rl_orp
Icc R/L Orp
Icc R/L Orp

Intraclass correlation between right and left Odds Ratio Product (ORP) across all epochs in Total Recording Time (TRT). A high correlation indicates good agreement in sleep depth between right and left hemispheres. The reasons for a low correlation could be:
a) reduced range of ORP across TRT (e.g., little stage wake or deep sleep)
b) systematic difference between the two electrodes (e.g. noise in one electrode or unilateral brain pathology)
c) true dissociation between right and left sleep (Dolphin sleep).

icc_ms_rows, icc_ms_col and icc_ms_error distinguish between these three possibilities, respectively.

Younes et al. 2021 (PubMed ID: 34156473)
Dres et al. 2019 (PubMed ID: 30818966)
Azarbarzin et al. 2021 (PubMed ID: 32441843)

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
intensity_scale
Arousal Characteristics - Intensity Scale
Arousal Characteristics - Intensity Scale

Arousal intensity on a scale from 1 to 9 (Younes 2017).

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
min_orp_firsthalf_nrem
Min ORP First Half NREM
Min ORP First Half NREM

Used (along with avg_orp_last120m_nrem) to calculate diff_orp.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
orpto9
Orp-9
Orp-9

Rate of sleep recovery following arousals. A high value reflects slow recovery and suggests high central arousability (Hyperarousal state).

Younes et al. 2021 (PubMed ID: 34156473)
Younes and Hanley 2016 (PubMed ID: 26718786)
Younes and Giannouli 2020 (PubMed ID: 31992415)

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
orp_type
ORP Type
ORP Type

Nine Odds Ratio Product (ORP) types with different potential mechanisms and associations with demographics, clinical phenotypes and outcomes. Source: sum_deciles_1and2 Younes et al. 2022 (PubMed ID: 35272350)

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
pct_epoch_0_25to0_5pct
Distribution of epochs in 0.25-0.5% ORP decile
Distribution of epochs in 0.25-0.5% ORP decile

Distribution of 30-s epochs, as a percent of total recording time in different Odds Ratio Product (ORP) deciles. Younes et al. 2022 (PubMed ID: 35272350)

ORP is a continuous index of sleep depth and wake propensity. A value of 0 indicates very deep sleep; a value of 2.5 indicates full wakefulness. These values are used to construct the ORP histogram and ORP phenotype (orp_type).

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
pct_epoch_0_5to0_75pct
Distribution of epochs in 0.5-0.75% ORP decile
Distribution of epochs in 0.5-0.75% ORP decile

Distribution of 30-s epochs, as a percent of total recording time in different Odds Ratio Product (ORP) deciles. Younes et al. 2022 (PubMed ID: 35272350)

ORP is a continuous index of sleep depth and wake propensity. A value of 0 indicates very deep sleep; a value of 2.5 indicates full wakefulness. These values are used to construct the ORP histogram and ORP phenotype (orp_type).

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
pct_epoch_0_75to1pct
Distribution of epochs in 0.75-1.0% ORP decile
Distribution of epochs in 0.75-1.0% ORP decile

Distribution of 30-s epochs, as a percent of total recording time in different Odds Ratio Product (ORP) deciles. Younes et al. 2022 (PubMed ID: 35272350)

ORP is a continuous index of sleep depth and wake propensity. A value of 0 indicates very deep sleep; a value of 2.5 indicates full wakefulness. These values are used to construct the ORP histogram and ORP phenotype (orp_type).

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
pct_epoch_0to_0_25pct
Distribution of epochs in 0-0.25% ORP decile
Distribution of epochs in 0-0.25% ORP decile

Distribution of 30-s epochs, as a percent of total recording time in different Odds Ratio Product (ORP) deciles. Younes et al. 2022 (PubMed ID: 35272350)

ORP is a continuous index of sleep depth and wake propensity. A value of 0 indicates very deep sleep; a value of 2.5 indicates full wakefulness. These values are used to construct the ORP histogram and ORP phenotype (orp_type).

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
pct_epoch_1_25to1_5pct
Distribution of epochs in 1.25-1.5% ORP decile
Distribution of epochs in 1.25-1.5% ORP decile

Distribution of 30-s epochs, as a percent of total recording time in different Odds Ratio Product (ORP) deciles. Younes et al. 2022 (PubMed ID: 35272350)

ORP is a continuous index of sleep depth and wake propensity. A value of 0 indicates very deep sleep; a value of 2.5 indicates full wakefulness. These values are used to construct the ORP histogram and ORP phenotype (orp_type).

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
pct_epoch_1_5to1_75pct
Distribution of epochs in 1.5-1.75% ORP decile
Distribution of epochs in 1.5-1.75% ORP decile

Distribution of 30-s epochs, as a percent of total recording time in different Odds Ratio Product (ORP) deciles. Younes et al. 2022 (PubMed ID: 35272350)

ORP is a continuous index of sleep depth and wake propensity. A value of 0 indicates very deep sleep; a value of 2.5 indicates full wakefulness. These values are used to construct the ORP histogram and ORP phenotype (orp_type).

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
pct_epoch_1_75to2pct
Distribution of epochs in 1.75-2.0% ORP decile
Distribution of epochs in 1.75-2.0% ORP decile

Distribution of 30-s epochs, as a percent of total recording time in different Odds Ratio Product (ORP) deciles. Younes et al. 2022 (PubMed ID: 35272350)

ORP is a continuous index of sleep depth and wake propensity. A value of 0 indicates very deep sleep; a value of 2.5 indicates full wakefulness. These values are used to construct the ORP histogram and ORP phenotype (orp_type).

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
pct_epoch_1to1_25pct
Distribution of epochs in 1.0-1.25% ORP decile
Distribution of epochs in 1.0-1.25% ORP decile

Distribution of 30-s epochs, as a percent of total recording time in different Odds Ratio Product (ORP) deciles. Younes et al. 2022 (PubMed ID: 35272350)

ORP is a continuous index of sleep depth and wake propensity. A value of 0 indicates very deep sleep; a value of 2.5 indicates full wakefulness. These values are used to construct the ORP histogram and ORP phenotype (orp_type).

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
pct_epoch_2_25to2_5pct
Distribution of epochs in 2.25-2.5% ORP decile
Distribution of epochs in 2.25-2.5% ORP decile

Distribution of 30-s epochs, as a percent of total recording time in different Odds Ratio Product (ORP) deciles. Younes et al. 2022 (PubMed ID: 35272350)

ORP is a continuous index of sleep depth and wake propensity. A value of 0 indicates very deep sleep; a value of 2.5 indicates full wakefulness. These values are used to construct the ORP histogram and ORP phenotype (orp_type).

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
pct_epoch_2to2_25pct
Distribution of epochs in 2.0-2.25% ORP decile
Distribution of epochs in 2.0-2.25% ORP decile

Distribution of 30-s epochs, as a percent of total recording time in different Odds Ratio Product (ORP) deciles. Younes et al. 2022 (PubMed ID: 35272350)

ORP is a continuous index of sleep depth and wake propensity. A value of 0 indicates very deep sleep; a value of 2.5 indicates full wakefulness. These values are used to construct the ORP histogram and ORP phenotype (orp_type).

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
powers_c3a2_alpha
Powers C3/A2 (mV^2) - Alpha (7.33-12.0)
Powers C3/A2 (mV^2) - Alpha (7.33-12.0)

Average power in all 3-s epochs in the indicated frequency range after excluding the highest 10% of values, which generally represent noise.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
powers_c3a2_beta1
Powers C3/A2 (mV^2) - Beta1 (14.3-20.0)
Powers C3/A2 (mV^2) - Beta1 (14.3-20.0)

Average power in all 3-s epochs in the indicated frequency range after excluding the highest 10% of values, which generally represent noise.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
powers_c3a2_beta2
Powers C3/A2 (mV^2) - Beta2 (20.3-35)
Powers C3/A2 (mV^2) - Beta2 (20.3-35)

Average power in all 3-s epochs in the indicated frequency range after excluding the highest 10% of values, which generally represent noise.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
powers_c3a2_delta
Powers C3/A2 (mV^2) - Delta (0.33-2.33 Hz)
Powers C3/A2 (mV^2) - Delta (0.33-2.33 Hz)

Average power in all 3-s epochs in the indicated frequency range after excluding the highest 10% of values, which generally represent noise.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
powers_c3a2_gammaomega
Powers C3/A2 (mV^2) - Gamma Omega (35.3-60.0)
Powers C3/A2 (mV^2) - Gamma Omega (35.3-60.0)

Average power in all 3-s epochs in the indicated frequency range after excluding the highest 10% of values, which generally represent noise.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
powers_c3a2_sigma
Powers C3/A2 (mV^2) - Sigma (12.33-14.0)
Powers C3/A2 (mV^2) - Sigma (12.33-14.0)

Average power in all 3-s epochs in the indicated frequency range after excluding the highest 10% of values, which generally represent noise.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
powers_c3a2_theta1
Powers C3/A2 (mV^2) - Theta1 (2.67-6.33)
Powers C3/A2 (mV^2) - Theta1 (2.67-6.33)

Average power in all 3-s epochs in the indicated frequency range after excluding the highest 10% of values, which generally represent noise.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
powers_c4a1_alpha
Powers C4/A1 (æV^2) - Alpha (7.33-12.0)
Powers C4/A1 (æV^2) - Alpha (7.33-12.0)

Average power in all 3-s epochs in the indicated frequency range after excluding the highest 10% of values, which generally represent noise.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
powers_c4a1_beta1
Powers C4/A1 (æV^2) - Beta1 (14.3-20.0)
Powers C4/A1 (æV^2) - Beta1 (14.3-20.0)

Average power in all 3-s epochs in the indicated frequency range after excluding the highest 10% of values, which generally represent noise.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
powers_c4a1_beta2
Powers C4/A1 (æV^2) - Beta2 (20.3-35.0)
Powers C4/A1 (æV^2) - Beta2 (20.3-35.0)

Average power in all 3-s epochs in the indicated frequency range after excluding the highest 10% of values, which generally represent noise.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
powers_c4a1_delta
Powers C4/A1 (æV^2) - Delta (0.33-2.33 Hz)
Powers C4/A1 (æV^2) - Delta (0.33-2.33 Hz)

Average power in all 3-s epochs in the indicated frequency range after excluding the highest 10% of values, which generally represent noise.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
powers_c4a1_gammaomega
Powers C4/A1 (æV^2) - Gamma Omega (35.3-60.0)
Powers C4/A1 (æV^2) - Gamma Omega (35.3-60.0)

Average power in all 3-s epochs in the indicated frequency range after excluding the highest 10% of values, which generally represent noise.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
powers_c4a1_sigma
Powers C4/A1 (æV^2) - Sigma (12.33-14.0)
Powers C4/A1 (æV^2) - Sigma (12.33-14.0)

Average power in all 3-s epochs in the indicated frequency range after excluding the highest 10% of values, which generally represent noise.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
powers_c4a1_theta1
Powers C4/A1 (æV^2) - Theta1 (2.67-6.33)
Powers C4/A1 (æV^2) - Theta1 (2.67-6.33)

Average power in all 3-s epochs in the indicated frequency range after excluding the highest 10% of values, which generally represent noise.

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
spindle_char_n2_density_c3
Spindle Characteristics (Stage N2) - Density (C3)
Spindle Characteristics (Stage N2) - Density (C3)

Spindle characteristics in stage N2. For detection methods and validation see Method A10: Goldschmied et al. 2021 (PubMed ID: 33165618), and Guadagni et al. 2021 (PubMed ID:32281182)

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
spindle_char_n2_density_c4
Spindle Characteristics (Stage N2) - Density (C4)
Spindle Characteristics (Stage N2) - Density (C4)

Spindle characteristics in stage N2. For detection methods and validation see Method A10: Goldschmied et al. 2021 (PubMed ID: 33165618), and Guadagni et al. 2021 (PubMed ID:32281182)

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
spindle_char_n2_freq_c3
Spindle Characteristics (Stage N2) - Frequency (C3)
Spindle Characteristics (Stage N2) - Frequency (C3)

Spindle characteristics in stage N2. For detection methods and validation see Method A10: Goldschmied et al. 2021 (PubMed ID: 33165618), and Guadagni et al. 2021 (PubMed ID:32281182)

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
spindle_char_n2_freq_c4
Spindle Characteristics (Stage N2) - Frequency (C4)
Spindle Characteristics (Stage N2) - Frequency (C4)

Spindle characteristics in stage N2. For detection methods and validation see Method A10: Goldschmied et al. 2021 (PubMed ID: 33165618), and Guadagni et al. 2021 (PubMed ID:32281182)

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
spindle_char_n2_pctfast_c3
Spindle Characteristics (Stage N2) - % Fast (C3)
Spindle Characteristics (Stage N2) - % Fast (C3)

Spindle characteristics in stage N2. For detection methods and validation see Method A10: Goldschmied et al. 2021 (PubMed ID: 33165618), and Guadagni et al. 2021 (PubMed ID:32281182)

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
spindle_char_n2_pctfast_c4
Spindle Characteristics (Stage N2) - % Fast (C4)
Spindle Characteristics (Stage N2) - % Fast (C4)

Spindle characteristics in stage N2. For detection methods and validation see Method A10: Goldschmied et al. 2021 (PubMed ID: 33165618), and Guadagni et al. 2021 (PubMed ID:32281182)

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
spindle_char_n2_power_c3
Spindle Characteristics (Stage N2) - Power (C3)
Spindle Characteristics (Stage N2) - Power (C3)

Spindle characteristics in stage N2. For detection methods and validation see Method A10: Goldschmied et al. 2021 (PubMed ID: 33165618), and Guadagni et al. 2021 (PubMed ID:32281182)

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
spindle_char_n2_power_c4
Spindle Characteristics (Stage N2) - Power (C4)
Spindle Characteristics (Stage N2) - Power (C4)

Spindle characteristics in stage N2. For detection methods and validation see Method A10: Goldschmied et al. 2021 (PubMed ID: 33165618), and Guadagni et al. 2021 (PubMed ID:32281182)

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
sum_deciles_1and2
Sum Deciles 1 & 2
Sum Deciles 1 & 2

Used to determine Odds Ratio Product type, see orp_type

Search for all EEG variables within this dataset

Sleep Monitoring/Polysomnography/Electroencephalogram
valid_delta_and_intensity_count
Arousal Characteristics - Valid Delta & Intensity Count
Arousal Characteristics - Valid Delta & Intensity Count Sleep Monitoring/Polysomnography/Electroencephalogram
valid_intensity_count
Arousal Characteristics - Valid Intensity Count
Arousal Characteristics - Valid Intensity Count Sleep Monitoring/Polysomnography/Electroencephalogram
beer10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): bottles or cans of beer before bed
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): bottles or cans of beer before bed

How many bottles or cans of beer 4 hours before going to sleep last night? (number, up to 2 digits)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
cgrtts10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): cigarettes before bed
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): cigarettes before bed

How many cigarettes 4 hours before going to sleep last night? (number, up to 2 digits)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
cigars10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): cigars before bed
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): cigars before bed

How many cigars 4 hours before going to sleep last night? (number, up to 2 digits)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
coffee10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): cups of coffee before bed
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): cups of coffee before bed

How many cups of coffee (with caffeine) 4 hours before going to sleep last night? (number, up to 2 digits)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
date10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): Date completed
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): Date completed

Date questionnaire was completed (days from index date)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
diffa10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): difficulty falling asleep
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): difficulty falling asleep

Did you have difficulty falling asleep last night?

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
hwlghr10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): How long slept (hours)
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): How long slept (hours)

How long did you sleep last night, Number of hours (number of hours, 0 to 24)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
hwlgmn10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): How long slept (minutes)
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): How long slept (minutes)

How long did you sleep last night, Number of minutes. (number of minutes, 0 to 59)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
hwwell10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): Quality of sleep compared to usual
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): Quality of sleep compared to usual

Compared to your usual night's sleep, how well did you sleep last night?

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
ltdp10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): Quality of sleep light/deep
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): Quality of sleep light/deep

Quality of sleep last night: light/deep (1=light to 5=deep)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
meds10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): medications before bed
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): medications before bed

Did you take any meds that you didn't tell us about yesterday? 0=No, 1=Yes, 2=Unsure (enter med names, digitized using meds software)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
minfa10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): minutes to fall asleep
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): minutes to fall asleep

How many minutes did it take for you to fall asleep at bedtime last night? (number of minutes, up to 3 digits)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
pipe10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): pipe bowls before bed
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): pipe bowls before bed

How many pipe bowls 4 hours before going to sleep last night? (number, up to 2 digits)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
plstc10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): discomfort from plastic piece over lip
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): discomfort from plastic piece over lip

How much discomfort caused by these parts of the monitor: plastic piece over lip?

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
rest10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): Quality of sleep: restless/restful
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): Quality of sleep: restless/restful

Quality of sleep: restless/restful (1=restless to 5=restful)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
shlg10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): Quality of sleep: short/long
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): Quality of sleep: short/long

Quality of sleep: short/long (1=short to 5=long)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
shots10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): mixed drinks before bed
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): mixed drinks before bed

How many mixed drinks or shots of liquor 4 hours before going to sleep last night? (number, up to 2 digits)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
soda10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): glasses or cans of soda before bed
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): glasses or cans of soda before bed

How many glasses or cans of soda (with caffeine) 4 hours before going to sleep last night? (number, up to 2 digits)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
tea10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): cups of tea before bed
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): cups of tea before bed

How many cups of tea (with caffeine) 4 hours before going to sleep last night? (number, up to 2 digits)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
vest10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): discomfort from vest
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): discomfort from vest

How much discomfort caused by these parts of the monitor: vest?

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
wine10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): glasses of wine before bed
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): glasses of wine before bed

How many glasses of wine 4 hours before going to sleep last night? (number, up to 2 digits)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
wrface10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): discomfort from wires on face
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): discomfort from wires on face

How much discomfort caused by these parts of the monitor: wires on face?

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
wrhead10
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): discomfort from wires on head
Morning Survey (Sleep Heart Health Study Visit One (SHHS1)): discomfort from wires on head

How much discomfort caused by these parts of the monitor: wires on your head?

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS1
formdate_ms
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): Date completed
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): Date completed

Date of Morning Survey form

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS2
ms204a
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): Quality of sleep light/deep
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): Quality of sleep light/deep

4. Rate the actual quality of your sleep last night (Do not compare to usual sleep quality). My sleep last night was (circle a number for each): a. [5 point Likert scale from "Light" to "Dark"]

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS2
ms204b
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): Quality of sleep: short/long
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): Quality of sleep: short/long

4. Rate the actual quality of your sleep last night (Do not compare to usual sleep quality). My sleep last night was (circle a number for each): b. [5 point Likert scale from "Short" to "Long"]

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS2
ms204c
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): Quality of sleep: restless/restful
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): Quality of sleep: restless/restful

4. Rate the actual quality of your sleep last night (Do not compare to usual sleep quality). My sleep last night was (circle a number for each): c. [5 point Likert scale from "Restless" to "Restful"]

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS2
ms205
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): Quality of sleep compared to usual
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): Quality of sleep compared to usual

5. Compared to your usual night's sleep, how well did you sleep last night? (check one)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS2
ms209a
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): glasses of wine before bed
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): glasses of wine before bed

9. How many of the following drinks did you have during the 4 hours before you went to sleep last night? (Please write "0" if you did not drink any of that beverage.) a. ____ glasses of wine (4 oz.)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS2
ms209b
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): mixed drinks before bed
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): mixed drinks before bed

9. How many of the following drinks did you have during the 4 hours before you went to sleep last night? (Please write "0" if you did not drink any of that beverage.) b. ____ drinks with hard liquor (1 shot)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS2
ms209c
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): bottles or cans of beer before bed
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): bottles or cans of beer before bed

9. How many of the following drinks did you have during the 4 hours before you went to sleep last night? (Please write "0" if you did not drink any of that beverage.) c. ____ bottles or cans of beer (12 oz.)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS2
ms210a
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): cups of coffee before bed
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): cups of coffee before bed

10. How many of the following drinks with caffeine did you have during the 4 hours before you went to sleep last night? (Please write "0" if you did not drink any of that beverage.) a. ____ cups of regular coffee (with caffeine)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS2
ms210b
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): cups of tea before bed
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): cups of tea before bed

10. How many of the following drinks with caffeine did you have during the 4 hours before you went to sleep last night? (Please write "0" if you did not drink any of that beverage.) b. ____ cups of tea (with caffeine)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS2
ms210c
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): glasses or cans of soda before bed
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): glasses or cans of soda before bed

10. How many of the following drinks with caffeine did you have during the 4 hours before you went to sleep last night? (Please write "0" if you did not drink any of that beverage.) c. ____ glasses or cans of cola or other soda (with caffeine)

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS2
ms211a
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): cigarettes before bed
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): cigarettes before bed

11. How much did you smoke during the 4 hours before you went to sleep last night? (Please write "0" for each that you did not smoke last night.) a. ____ number of cigarettes

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS2
ms211b
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): pipe bowls before bed
Morning Survey (Sleep Heart Health Study Visit Two (SHHS2)): pipe bowls before bed

11. How much did you smoke during the 4 hours before you went to sleep last night? (Please write "0" for each that you did not smoke last night.) b. ____ number of pipe bowls

Sleep Monitoring/Polysomnography/Evening and Morning Survey/SHHS2