The settings below represent the standards set at the beginning of the project. There may be a small proportion of studies and signals that do not match these standards exactly. Please review the settings at the individual sleep study level as you proceed with any analyses.

CFSv1

Channel Channel Derivation Sampling Rate (Hz) Hardware Filters (Hz) Sensor Type
C3 C3/A2 128 High Pass .16/Low Pass 105 Gold cup electrode
C4 C4/A1 128 High Pass .16/Low Pass 105 Gold cup electrode
A1 128 High Pass .16/Low Pass 105 Gold cup electrode
A2 128 High Pass .16/Low Pass 105 Gold cup electrode
LOC LOC/A2 128 High Pass .16/Low Pass 105 Gold cup electrode
ROC ROC/A1 128 High Pass .16/Low Pass 105 Gold cup electrode
ECG2 ECG2/ECG1 256 High Pass .16/Low Pass 105 Ag/AgCl patch
ECG1 ECG1/ECG2 256 High Pass .16/Low Pass 105 Ag/AgCl patch
EMG1 EMG1/EMG2 256 High Pass .16/Low Pass 105 Gold cup electrode
EMG2 EMG2/EMG1 256 High Pass .16/Low Pass 105 Gold cup electrode
EMG3 256 High Pass .16/Low Pass 105 Gold cup electrode
L Leg 64 High Pass .16/Low Pass 105 Compumedics piezo leg leads
R Leg 64 High Pass .16/Low Pass 105 Compumedics piezo leg leads
Airflow 32 Compumedics thermistor
Thor Effort 32 Compumedics Summit IP RIP
Abdo Effort 32 Compumedics Summit IP RIP
Sum 32 Compumedics Summit IP RIP
Snore 256 Compumedics snore mic
Position 1 Compumedics external position sensor
Ox Status 1 Nonin 8000 sensor
Pulse 1 Nonin 8000 sensor
SpO2 1 Nonin 8000 sensor
Nasal Pres 64 Nasal cannula
PlethWV 128 Nonin 8000 sensor

CFSv2

Channel Channel Derivation Sampling Rate (Hz) Hardware Filters (Hz) Sensor Type
C3 C3/A2 128 High Pass .16/Low Pass 105 Gold cup electrode
C4 C4/A1 128 High Pass .16/Low Pass 105 Gold cup electrode
A1 128 High Pass .16/Low Pass 105 Gold cup electrode
A2 128 High Pass .16/Low Pass 105 Gold cup electrode
LOC LOC/A2 128 High Pass .16/Low Pass 105 Gold cup electrode
ROC ROC/A1 128 High Pass .16/Low Pass 105 Gold cup electrode
ECG2 ECG2/ECG1 512 High Pass .16/Low Pass 105 Ag/AgCl patch
ECG1 ECG1/ECG2 512 High Pass .16/Low Pass 105 Ag/AgCl patch
EMG1 EMG1/EMG2 256 High Pass .16/Low Pass 105 Gold cup electrode
EMG2 EMG2/EMG1 256 High Pass .16/Low Pass 105 Gold cup electrode
EMG3 256 High Pass .16/Low Pass 105 Gold cup electrode
L Leg 64 High Pass .16/Low Pass 105 Compumedics piezo leg leads
R Leg 64 High Pass .16/Low Pass 105 Compumedics piezo leg leads
Airflow 32 Compumedics thermistor
Thor Effort 32 Compumedics Summit IP RIP
Abdo Effort 32 Compumedics Summit IP RIP
Sum 32 Compumedics Summit IP RIP
Snore 256 Compumedics snore mic
Position 1 Compumedics external position sensor
Ox Status 1 Nonin 8000 sensor
Pulse 1 Nonin 8000 sensor
SpO2 1 Nonin 8000 sensor
Nasal Pres 128 Nasal cannula
  • CFS v1 and v2 montage differences are changes in sampling rate.