Cleveland Family Study
Docs
Files
Variables
Show menu
Hide menu
cfs
pages
manuals
polysomnography
17.0 Table of Contents - Polysomnography
17.1 Materials Needed
17.2 PSG Training and Certification Requirements
17.2.1 Certification
17.3 Prior to the Visit
17.3.1 Participant Preparation
17.3.2 Equipment Preparation
17.3.2.1 Control Module
17.3.2.2 Patient Interface Box (PIB)
17.3.2.3 Table 1: PIB Configuration for the Family Study
17.3.2.4 Table 2: Display Name and Wire Descriptions
17.3.2.5 Family Study Template and Polygraph Setup
17.3.2.6 Table 3: Channels and Sampling Rates for the Family Study
17.3.2.7 Table 4: Trace Settings for the Family Study
17.4 The In-Lab Visit
17.5 The Setting
17.6 Sensor Placement
17.7 Suggested Order of PSG Hook-Up
17.8 PSG Hook-Up Procedures
17.8.1 Step 1: Attachment of ECG Electrodes
17.8.2 Step 2: Placement of Respiratory Bands
17.8.3 Step 3: Apply EEG Scalp Electrodes (Gold Disk)
17.8.3.1 Identify Your Landmarks
17.8.3.2 Measure for Electrode Sites
17.8.3.3 Table 5: Quick Reference Measurement Chart
17.8.3.4 To Determine CZ (Common Ground)
17.8.3.5 To Determine C4
17.8.3.6 To Determine C3
17.8.3.7 To Determine O1 and O2
17.8.3.8 To Determine A1 and A2
17.8.3.9 To Determine EOG Placements
17.8.3.10 To Determine EMG Placements
17.8.3.11 Prepare the Electrode Sites
17.8.3.12 Attach Gold Disk Electrodes
17.8.3.13 Attachement Sites for Gold Disk Electrodes
17.8.3.14 Techniques for Disk Electrode Application
17.8.4 Step 4: Attach the Position Sensor
17.8.5 Step 5: Attach Oximeter
17.8.5.1 Disposable Probe
17.8.5.2 Non-Disposable Probe
17.8.6 Step 6: Attach Thermistor
17.8.7 Step 7: Attach Nasal Cannula
17.8.8 Step 8: Attach Leg Sensors
17.8.9 Step 9: Attach Snore Microphone
17.9 Signal Verification
17.9.1 Signal Verification Form
17.9.2 Impedance and Signal Quality Overview
17.9.2.1 If All Electrodes Register High
17.9.2.2 If Only Certain Electrodes Register High
17.9.3 Impedance and Signal Quality Procedure
17.9.4 Troubleshooting Bad Signals
17.9.5 Priority of Signals
17.9.6 Final Sensor Equipment Check
17.10 Recording the PSG
17.10.1 Starting a New Study
17.10.2 Set the Computer to Record the Sleep Study
17.11 Leaving the Lab
17.12 Morning Arrival
17.13 Data Collection
17.13.1 Automatic Analysis
17.13.2 Saving the Sleep Study on CD-ROM
17.13.3 Opening the Study from the CD in Profusion
17.13.4 Creating Family Participant Feedback Report
17.13.5 Reviewing Medical Alerts
17.13.6 Creating SAS Reports
17.14 Scoring Procedures
17.14.1 Sleep Staging and Arousals
17.14.2 Setting Lights
17.14.3 Respiratory Events
17.14.4 Patient Information Window
17.15 Checking Outliers After Scoring
17.15.1 Checking Outliers Procedure
17.15.2 Troubleshooting
17.16 PSG Equipment Care and Maintenance
17.16.1 Electrode Overview
17.16.1.1 Keep Gold Disks Clean
17.16.1.2 Disinfect Gold Disks Between Participants
17.16.1.3 Treat Electrode Wires with Respect
17.16.1.4 Cleaning and Disinfection Before the First Use
17.16.2 Cleaning and Disinfection of Equipment
17.16.2.1 Methods for Cleaning/Disinfection
17.16.2.2 Gold Disk Electrodes
17.16.2.3 Thermistor
17.16.2.4 Oximeter Probe, Position Sensor, and ECG Electrode Wires
17.16.2.5 Respiratory Band Covers
17.16.3 Masimo Calibration Procedures
17.16.4 Body Position Sensor Calibration Procedures
Table of Contents - Manuals
17.1 Materials Needed
cfs
polysomnography
17-00-polysomnography-toc.md
17-01-materials-needed.md
17-02-psg-training-cert.md
17-03-01-ppt-prep.md
17-03-02-equipment-prep.md
17-04-in-lab-visit.md
17-05-the-setting.md
17-06-sensor-placement.md
17-07-suggested-order-psg-hookup.md
17-08-01-step1.md
17-08-02-step2.md
17-08-03-00-step3.md
17-08-03-01-identify-landmarks.md
17-08-03-02-measure-electrode-sites.md
17-08-03-03-table5-measurement-chart.md
17-08-03-04-determine-cz.md
17-08-03-05-determine-c4.md
17-08-03-06-determine-c3.md
17-08-03-07-determine-o1-o2.md
17-08-03-08-determine-a1-a2.md
17-08-03-09-determine-eog.md
17-08-03-10-determine-emg.md
17-08-03-11-prep-electrode-sites.md
17-08-03-12-attach-electrodes.md
17-08-03-13-attachment-sites.md
17-08-03-14-techniques-application.md
17-08-04-step4.md
17-08-05-step5.md
17-08-06-step6.md
17-08-07-step7.md
17-08-08-step8.md
17-08-09-step9.md
17-09-01-signal-verification-form.md
17-09-02-impedance-signal-quality-overview.md
17-09-03-impedance-signal-procedure.md
17-09-04-troubleshooting.md
17-09-05-signals-priority.md
17-09-06-sensor-equipment-check.md
17-10-recording-psg.md
17-11-leaving-lab.md
17-12-morning-arrival.md
17-13-00-data-collection.md
17-13-01-automatic-analysis.md
17-13-02-saving-sleep-study.md
17-13-03-opening-study.md
17-13-04-family-ppt-feedback-report.md
17-13-05-reviewing-med-alerts.md
17-13-06-creating-sas-reports.md
17-14-scoring-procedures.md
17-15-00-checking-outliers.md
17-15-01-checking-outliers-procedure.md
17-15-02-troubleshooting.md
17-16-01-electrode-overview.md
17-16-02-clean-disinfect.md
17-16-03-masimo-calibration.md
17-16-04-position-sensor-calibration.md