Name | Label | Folder | |
---|---|---|---|
ahilt2
Obstructive Apnea Index (OAI) < 1 and Apnea-Hypopnea Index (AHI) < 2 (normal range) = 1 Ineligible Normal
|
Obstructive Apnea Index (OAI) < 1 and Apnea-Hypopnea Index (AHI) < 2 (normal range) = 1 Ineligible Normal | Sleep Monitoring/Polysomnography/Signal Quality | |
capdur
Hours of usable cap
|
Hours of usable cap
Hours of usable cap signal - requires use of calibrated channel type with upper and lower limits for valid signal |
Sleep Monitoring/Polysomnography/Signal Quality | |
overall
Overall study grade
|
Overall study grade | Sleep Monitoring/Polysomnography/Signal Quality | |
oximdur
Hours of usable oximetry
|
Hours of usable oximetry | Sleep Monitoring/Polysomnography/Signal Quality | |
posn
Position sensor working
|
Position sensor working | Sleep Monitoring/Polysomnography/Signal Quality | |
qucap
Quality of cap
|
Quality of cap
usable mainly artifact free signal |
Sleep Monitoring/Polysomnography/Signal Quality | |
quco2
Quality of carbon dioxide (CO2)
|
Quality of carbon dioxide (CO2) | Sleep Monitoring/Polysomnography/Signal Quality | |
quoxim
Quality of oximetry
|
Quality of oximetry | Sleep Monitoring/Polysomnography/Signal Quality | |
abdodur
Hours of usable abdominal effort
|
Hours of usable abdominal effort | Sleep Monitoring/Polysomnography/Signal Quality | |
abnoreeg
Abnormal EEG background / waveforms
|
Abnormal EEG background / waveforms
1=Unusual Occurrences - Abnormal EEG |
Sleep Monitoring/Polysomnography/Signal Quality | |
ahiov20
Obstructive Apnea Index (OAI) > 15 or Apnea-Hypopnea Index (AHI) > 20 = 1 Surgeon Alert
|
Obstructive Apnea Index (OAI) > 15 or Apnea-Hypopnea Index (AHI) > 20 = 1 Surgeon Alert | Sleep Monitoring/Polysomnography/Signal Quality | |
ahiov30
Urgent Referral - Obstructive Apnea Index (OAI) > 20 or Apnea-Hypopnea Index (AHI) > 30 = 1 Urgent Ineligible
|
Urgent Referral - Obstructive Apnea Index (OAI) > 20 or Apnea-Hypopnea Index (AHI) > 30 = 1 Urgent Ineligible | Sleep Monitoring/Polysomnography/Signal Quality | |
airdur
Hours of usable airflow
|
Hours of usable airflow | Sleep Monitoring/Polysomnography/Signal Quality | |
alpdel
Physiologic alpha intrusion
|
Physiologic alpha intrusion
1=Unusual Occurrences - Alpha intrusion |
Sleep Monitoring/Polysomnography/Signal Quality | |
apnhyppr
Scoring Apnea/Hypopnea unreliable
|
Scoring Apnea/Hypopnea unreliable
1=Apnea/Hypopnea distinction unreliable (when airflow signal is artifactual or absent for over 20 % of scored respiratory events) |
Sleep Monitoring/Polysomnography/Signal Quality | |
arsl3ou
Arousal index < 3 verified
|
Arousal index < 3 verified
1=Outlier - arousal index < 3 verified |
Sleep Monitoring/Polysomnography/Signal Quality | |
artifact
Total artifact time (Unscorable)
|
Total artifact time (Unscorable)
Total minutes of unscorable (artifact) data |
Sleep Monitoring/Polysomnography/Signal Quality | |
arunrel
Scoring arousals unreliable
|
Scoring arousals unreliable
1=Arousals unreliable (when the technical quality of the study does not allow one to distinguish discrete increases in EEG frequency from background changes in EEG. EEG still may be of sufficient quality to score stages. Studies with the physiological alpha intrusion will have arousals scored regardless of difficulty) |
Sleep Monitoring/Polysomnography/Signal Quality | |
c3dur
Hours of usable C3
|
Hours of usable C3 | Sleep Monitoring/Polysomnography/Signal Quality | |
c4dur
Hours of usable C4
|
Hours of usable C4 | Sleep Monitoring/Polysomnography/Signal Quality | |
candur
Hours of usable cannula
|
Hours of usable cannula | Sleep Monitoring/Polysomnography/Signal Quality | |
chestdur
Hours of usable chest effort
|
Hours of usable chest effort | Sleep Monitoring/Polysomnography/Signal Quality | |
chindur
Hours of usable chin
|
Hours of usable chin | Sleep Monitoring/Polysomnography/Signal Quality | |
eogldur
Hours of usable EOG L
|
Hours of usable EOG L | Sleep Monitoring/Polysomnography/Signal Quality | |
eogrdur
Hours of usable EOG R
|
Hours of usable EOG R | Sleep Monitoring/Polysomnography/Signal Quality | |
f3dur
Hours of usable F3
|
Hours of usable F3 | Sleep Monitoring/Polysomnography/Signal Quality | |
f4dur
Hours of usable F4
|
Hours of usable F4 | Sleep Monitoring/Polysomnography/Signal Quality | |
hrdur
Hours of usable heart rate
|
Hours of usable heart rate | Sleep Monitoring/Polysomnography/Signal Quality | |
legldur
Hours of usable legL
|
Hours of usable legL | Sleep Monitoring/Polysomnography/Signal Quality | |
legrdur
Hours of usable legR
|
Hours of usable legR | Sleep Monitoring/Polysomnography/Signal Quality | |
losbeg
Data lost - recording begain in sleep
|
Data lost - recording begain in sleep
1=data lost - loss at beginning of study |
Sleep Monitoring/Polysomnography/Signal Quality | |
losoth
Data lost - other
|
Data lost - other
1=data lost - other |
Sleep Monitoring/Polysomnography/Signal Quality | |
m1dur
Hours of usable M1
|
Hours of usable M1 | Sleep Monitoring/Polysomnography/Signal Quality | |
m2dur
hours of usable M2
|
hours of usable M2 | Sleep Monitoring/Polysomnography/Signal Quality | |
maxresou30
Maximum length respiratory event >30 seconds verified
|
Maximum length respiratory event >30 seconds verified
1=Outlier - max length respiratory event > 30 seconds verified |
Sleep Monitoring/Polysomnography/Signal Quality | |
npflow
Flow limitation
|
Flow limitation
1=flow limitation observed |
Sleep Monitoring/Polysomnography/Signal Quality | |
o1dur
Hours of usable O1
|
Hours of usable O1 | Sleep Monitoring/Polysomnography/Signal Quality | |
o2dur
Hours of usable O2
|
Hours of usable O2 | Sleep Monitoring/Polysomnography/Signal Quality | |
otherou
Other outlier
|
Other outlier
1=Outlier - other |
Sleep Monitoring/Polysomnography/Signal Quality | |
period
Periodic breathing >= 10 minutes
|
Periodic breathing >= 10 minutes
1=unusual occurrences - periodic breathing > 5 minutes |
Sleep Monitoring/Polysomnography/Signal Quality | |
plmou25
Periodic limb movement (PLM) > 25 verified (must be in sleep)
|
Periodic limb movement (PLM) > 25 verified (must be in sleep)
1=Outlier - Periodic limb movement (PLM) > 25 verified |
Sleep Monitoring/Polysomnography/Signal Quality | |
processdt
Date data were processed
|
Date data were processed | Sleep Monitoring/Polysomnography/Signal Quality | |
psndur
Hours of usable position
|
Hours of usable position
*All non-compumedics collected studies have position hand scored by scorer from notes supplied by site / none of position signals transfer in European Data Format (EDF) only numbers |
Sleep Monitoring/Polysomnography/Signal Quality | |
pwfdur
Hours of usable pleth wave form
|
Hours of usable pleth wave form | Sleep Monitoring/Polysomnography/Signal Quality | |
qsahi
Apnea-Hypopnea Index (AHI)
|
Apnea-Hypopnea Index (AHI)
Recorded by the scorer on QS form |
Sleep Monitoring/Polysomnography/Signal Quality | |
qsoai
Obstructive apnea index (OAI)
|
Obstructive apnea index (OAI)
Recorded by the scorer on QS form |
Sleep Monitoring/Polysomnography/Signal Quality | |
quabdo
Quality of abdominal effort
|
Quality of abdominal effort | Sleep Monitoring/Polysomnography/Signal Quality | |
quair
Quality of airflow
|
Quality of airflow | Sleep Monitoring/Polysomnography/Signal Quality | |
quc3
Quality of C3
|
Quality of C3
Quality of EEG |
Sleep Monitoring/Polysomnography/Signal Quality | |
quc4
Quality of C4
|
Quality of C4
Quality of EEG |
Sleep Monitoring/Polysomnography/Signal Quality | |
qucan
Quality of cannula
|
Quality of cannula | Sleep Monitoring/Polysomnography/Signal Quality | |
quchest
Quality of chest effort
|
Quality of chest effort | Sleep Monitoring/Polysomnography/Signal Quality | |
quchin
Quality of chin
|
Quality of chin | Sleep Monitoring/Polysomnography/Signal Quality | |
queogl
Quality of EOG L
|
Quality of EOG L | Sleep Monitoring/Polysomnography/Signal Quality | |
queogr
Quality of EOG R
|
Quality of EOG R | Sleep Monitoring/Polysomnography/Signal Quality | |
quf3
Quality of F3
|
Quality of F3
Quality of EEG |
Sleep Monitoring/Polysomnography/Signal Quality | |
quf4
Quality of F4
|
Quality of F4
Quality of EEG |
Sleep Monitoring/Polysomnography/Signal Quality | |
quhr
Quality of hr
|
Quality of hr | Sleep Monitoring/Polysomnography/Signal Quality | |
qulegl
Quality of LegL
|
Quality of LegL | Sleep Monitoring/Polysomnography/Signal Quality | |
qulegr
Quality of LegR
|
Quality of LegR | Sleep Monitoring/Polysomnography/Signal Quality | |
qum1
Quality of M1
|
Quality of M1
Quality of EEG |
Sleep Monitoring/Polysomnography/Signal Quality | |
qum2
Quality of M2
|
Quality of M2
Quality of EEG |
Sleep Monitoring/Polysomnography/Signal Quality | |
quo1
Quality of O1
|
Quality of O1
Quality of EEG |
Sleep Monitoring/Polysomnography/Signal Quality | |
quo2
Quality of O2
|
Quality of O2
Quality of EEG |
Sleep Monitoring/Polysomnography/Signal Quality | |
qupsn
Quality of position
|
Quality of position
*position for all non-compumedics data hand scored from notes from site tech |
Sleep Monitoring/Polysomnography/Signal Quality | |
qupwf
Quality of pleth wave form
|
Quality of pleth wave form | Sleep Monitoring/Polysomnography/Signal Quality | |
quref
Quality of reference
|
Quality of reference | Sleep Monitoring/Polysomnography/Signal Quality | |
qusnor
Quality of snore
|
Quality of snore
Quality of snore microphone |
Sleep Monitoring/Polysomnography/Signal Quality | |
qusum
Quality of SUM
|
Quality of SUM
Quality of SUM channel |
Sleep Monitoring/Polysomnography/Signal Quality | |
qut3
Quality of T3
|
Quality of T3 | Sleep Monitoring/Polysomnography/Signal Quality | |
qut4
Quality of T4
|
Quality of T4 | Sleep Monitoring/Polysomnography/Signal Quality | |
rcvddt
Date received at reading center
|
Date received at reading center | Sleep Monitoring/Polysomnography/Signal Quality | |
recbeaw
Data lost - recording ended before waking
|
Data lost - recording ended before waking
1=data Lost - recording ended before wake |
Sleep Monitoring/Polysomnography/Signal Quality | |
remarunrel
Scoring arousals in rapid eye movement sleep (REM) (only) unreliable
|
Scoring arousals in rapid eye movement sleep (REM) (only) unreliable
1=arousals in rapid eye movement sleep (REM) unreliable (when EMG is artifactual or absent during all or rapid eye movement sleep (REM) portion of the study) |
Sleep Monitoring/Polysomnography/Signal Quality | |
remnrempr
Scoring rapid eye movement sleep (REM)/non-rapid eye movement sleep (NREM) unreliable
|
Scoring rapid eye movement sleep (REM)/non-rapid eye movement sleep (NREM) unreliable
1=Sleep staging problem - scoring rapid eye movement sleep (REM)/non-rapid eye movement sleep (NREM) unreliable (when identification of Stage rapid eye movement sleep (REM) is unreliable (usually due to poor or missing EMG or when both EOGs are absent)) |
Sleep Monitoring/Polysomnography/Signal Quality | |
respevpr
Scoring respiratory events (Respiratory Disturbance Index (RDI)) unreliable
|
Scoring respiratory events (Respiratory Disturbance Index (RDI)) unreliable
1=Problems with respiratory events (when due to the technical quality of the respiratory signals, distinctions between hypopneas and normal breaths are equivocal in over 20 % of scored events; also when the quality of the oximetry signal raises doubts about actual magnitude of desaturation linked with over 20 % of respiratory events (unstable baseline) |
Sleep Monitoring/Polysomnography/Signal Quality | |
rsnco
Reason for study failure
|
Reason for study failure | Sleep Monitoring/Polysomnography/Signal Quality | |
sa02lt90
Urgent referral - oxygen saturation (SaO2) <90% >2% sleep time = 1 urgent ineligible
|
Urgent referral - oxygen saturation (SaO2) <90% >2% sleep time = 1 urgent ineligible
*Note studies that have oximetry problems here |
Sleep Monitoring/Polysomnography/Signal Quality | |
sa02lt92
Urgent referral - oxygen saturation (SaO2) <92% >2% sleep time = 1 Surgeon alert
|
Urgent referral - oxygen saturation (SaO2) <92% >2% sleep time = 1 Surgeon alert
*Note studies that have oximetry problems here |
Sleep Monitoring/Polysomnography/Signal Quality | |
scordt
Date scored
|
Date scored
Date scoring performed at reading center |
Sleep Monitoring/Polysomnography/Signal Quality | |
slewake
Study scored sleep wake = 1, all sleep scored stage 2
|
Study scored sleep wake = 1, all sleep scored stage 2
1=Study scored sleep wake |
Sleep Monitoring/Polysomnography/Signal Quality | |
snordur
Hours of usable snore
|
Hours of usable snore | Sleep Monitoring/Polysomnography/Signal Quality | |
staendt
Week ending date
|
Week ending date | Sleep Monitoring/Polysomnography/Signal Quality | |
status
Pass fail status (passed=1 failed=2)
|
Pass fail status (passed=1 failed=2) | Sleep Monitoring/Polysomnography/Signal Quality | |
stg1stg2pr
Scoring stage1/ stage 2 unreliable
|
Scoring stage1/ stage 2 unreliable
1=Sleep staging problem - scoring stage1/stage2 unreliable (when K-complexes and sleep spindles do not have show their classical morphology and distinction between Stage 1 and Stage 2 is doubtful (characteristic for the studies with low voltage EEG)) |
Sleep Monitoring/Polysomnography/Signal Quality | |
stg2stg3pr
Scoring stage2/ deep sleep unreliable
|
Scoring stage2/ deep sleep unreliable
1=sleep staging problem - scoring stage2/stage3-4 unreliable (when distinction between Stage 2 and Deep Sleep is unreliable because of EEG artifact (usually due to the respiratory or sweat artifact on the EEG, and High Pass filter =1Hz used)) |
Sleep Monitoring/Polysomnography/Signal Quality | |
stlonp
Lights on set by scorer
|
Lights on set by scorer
Lights on time - end of in-bed period set by scorer |
Sleep Monitoring/Polysomnography/Signal Quality | |
sumdur
Hours of usable SUM
|
Hours of usable SUM | Sleep Monitoring/Polysomnography/Signal Quality | |
t3dur
Hours of usable T3
|
Hours of usable T3
Hours of usable EEG |
Sleep Monitoring/Polysomnography/Signal Quality | |
t4dur
Hours of usable T4
|
Hours of usable T4
Hours of usable EEG |
Sleep Monitoring/Polysomnography/Signal Quality | |
unuhroth
Urgent - other heart rate arrhythmia, heart block, v-tach, etc. = 1 urgent ineligible
|
Urgent - other heart rate arrhythmia, heart block, v-tach, etc. = 1 urgent ineligible | Sleep Monitoring/Polysomnography/Signal Quality | |
unuhrou
Urgent - problem heart rate < 40 bpm or > 140 bpm > 2 minutes = 1 urgent ineligible
|
Urgent - problem heart rate < 40 bpm or > 140 bpm > 2 minutes = 1 urgent ineligible
1=Medical alert for unusual heart rate or electrocardiogram (ECG) |
Sleep Monitoring/Polysomnography/Signal Quality | |
unustgou
Extreme staging distribution
|
Extreme staging distribution
1=outlier - unusual staging |
Sleep Monitoring/Polysomnography/Signal Quality | |
wakslepr
Scoring stage wake/sleep unreliable
|
Scoring stage wake/sleep unreliable
1=Sleep staging problem - scoring wake/sleep unreliable (when the clarity of the EEG makes distinguishing the transition unreliable) |
Sleep Monitoring/Polysomnography/Signal Quality |