We use cookies and other tools to enhance your experience on our website and to analyze our web traffic.
For more information about these cookies and the data collected, please refer to our Privacy Policy.

Childhood Adenotonsillectomy Trial

Name Label Folder
ahilt2
Obstructive Apnea Index (OAI) < 1 and Apnea-Hypopnea Index (AHI) < 2 (normal range) = 1 Ineligible Normal
Obstructive Apnea Index (OAI) < 1 and Apnea-Hypopnea Index (AHI) < 2 (normal range) = 1 Ineligible Normal Sleep Monitoring/Polysomnography/Signal Quality
capdur
Hours of usable cap
Hours of usable cap

Hours of usable cap signal - requires use of calibrated channel type with upper and lower limits for valid signal

Sleep Monitoring/Polysomnography/Signal Quality
eliginelig
Eligibility status by Polysomnography (PSG)
Eligibility status by Polysomnography (PSG)

Ineligible if omahi3 <2 and omai0p<1 or meets any of urgent criteria variables ahiov30=1, saO2lt90=1, unuhrou=1,unuhroth=1

Sleep Monitoring/Polysomnography/Signal Quality
overall
Overall study grade
Overall study grade Sleep Monitoring/Polysomnography/Signal Quality
oximdur
Hours of usable oximetry
Hours of usable oximetry Sleep Monitoring/Polysomnography/Signal Quality
posn
Position sensor working
Position sensor working Sleep Monitoring/Polysomnography/Signal Quality
qucap
Quality of cap
Quality of cap

usable mainly artifact free signal

Sleep Monitoring/Polysomnography/Signal Quality
quco2
Quality of carbon dioxide (CO2)
Quality of carbon dioxide (CO2) Sleep Monitoring/Polysomnography/Signal Quality
quoxim
Quality of oximetry
Quality of oximetry Sleep Monitoring/Polysomnography/Signal Quality
stdydt
Date of study
Date of study Sleep Monitoring/Polysomnography/Signal Quality
abdodur
Hours of usable abdominal effort
Hours of usable abdominal effort Sleep Monitoring/Polysomnography/Signal Quality
abnoreeg
Abnormal EEG background / waveforms
Abnormal EEG background / waveforms

1=Unusual Occurrences - Abnormal EEG

Sleep Monitoring/Polysomnography/Signal Quality
ahiov20
Obstructive Apnea Index (OAI) > 15 or Apnea-Hypopnea Index (AHI) > 20 = 1 Surgeon Alert
Obstructive Apnea Index (OAI) > 15 or Apnea-Hypopnea Index (AHI) > 20 = 1 Surgeon Alert Sleep Monitoring/Polysomnography/Signal Quality
ahiov30
Urgent Referral - Obstructive Apnea Index (OAI) > 20 or Apnea-Hypopnea Index (AHI) > 30 = 1 Urgent Ineligible
Urgent Referral - Obstructive Apnea Index (OAI) > 20 or Apnea-Hypopnea Index (AHI) > 30 = 1 Urgent Ineligible Sleep Monitoring/Polysomnography/Signal Quality
airdur
Hours of usable airflow
Hours of usable airflow Sleep Monitoring/Polysomnography/Signal Quality
alpdel
Physiologic alpha intrusion
Physiologic alpha intrusion

1=Unusual Occurrences - Alpha intrusion

Sleep Monitoring/Polysomnography/Signal Quality
apnhyppr
Scoring Apnea/Hypopnea unreliable
Scoring Apnea/Hypopnea unreliable

1=Apnea/Hypopnea distinction unreliable (when airflow signal is artifactual or absent for over 20 % of scored respiratory events)

Sleep Monitoring/Polysomnography/Signal Quality
arsl3ou
Arousal index < 3 verified
Arousal index < 3 verified

1=Outlier - arousal index < 3 verified

Sleep Monitoring/Polysomnography/Signal Quality
artifact
Total artifact time (Unscorable)
Total artifact time (Unscorable)

Total minutes of unscorable (artifact) data

Sleep Monitoring/Polysomnography/Signal Quality
arunrel
Scoring arousals unreliable
Scoring arousals unreliable

1=Arousals unreliable (when the technical quality of the study does not allow one to distinguish discrete increases in EEG frequency from background changes in EEG. EEG still may be of sufficient quality to score stages. Studies with the physiological alpha intrusion will have arousals scored regardless of difficulty)

Sleep Monitoring/Polysomnography/Signal Quality
c3dur
Hours of usable C3
Hours of usable C3 Sleep Monitoring/Polysomnography/Signal Quality
c4dur
Hours of usable C4
Hours of usable C4 Sleep Monitoring/Polysomnography/Signal Quality
candur
Hours of usable cannula
Hours of usable cannula Sleep Monitoring/Polysomnography/Signal Quality
chestdur
Hours of usable chest effort
Hours of usable chest effort Sleep Monitoring/Polysomnography/Signal Quality
chindur
Hours of usable chin
Hours of usable chin Sleep Monitoring/Polysomnography/Signal Quality
eogldur
Hours of usable EOG L
Hours of usable EOG L Sleep Monitoring/Polysomnography/Signal Quality
eogrdur
Hours of usable EOG R
Hours of usable EOG R Sleep Monitoring/Polysomnography/Signal Quality
f3dur
Hours of usable F3
Hours of usable F3 Sleep Monitoring/Polysomnography/Signal Quality
f4dur
Hours of usable F4
Hours of usable F4 Sleep Monitoring/Polysomnography/Signal Quality
hrdur
Hours of usable heart rate
Hours of usable heart rate Sleep Monitoring/Polysomnography/Signal Quality
legldur
Hours of usable legL
Hours of usable legL Sleep Monitoring/Polysomnography/Signal Quality
legrdur
Hours of usable legR
Hours of usable legR Sleep Monitoring/Polysomnography/Signal Quality
losbeg
Data lost - recording begain in sleep
Data lost - recording begain in sleep

1=data lost - loss at beginning of study

Sleep Monitoring/Polysomnography/Signal Quality
losoth
Data lost - other
Data lost - other

1=data lost - other

Sleep Monitoring/Polysomnography/Signal Quality
m1dur
Hours of usable M1
Hours of usable M1 Sleep Monitoring/Polysomnography/Signal Quality
m2dur
hours of usable M2
hours of usable M2 Sleep Monitoring/Polysomnography/Signal Quality
maxresou30
Maximum length respiratory event >30 seconds verified
Maximum length respiratory event >30 seconds verified

1=Outlier - max length respiratory event > 30 seconds verified

Sleep Monitoring/Polysomnography/Signal Quality
npflow
Flow limitation
Flow limitation

1=flow limitation observed

Sleep Monitoring/Polysomnography/Signal Quality
o1dur
Hours of usable O1
Hours of usable O1 Sleep Monitoring/Polysomnography/Signal Quality
o2dur
Hours of usable O2
Hours of usable O2 Sleep Monitoring/Polysomnography/Signal Quality
otherou
Other outlier
Other outlier

1=Outlier - other

Sleep Monitoring/Polysomnography/Signal Quality
period
Periodic breathing >= 10 minutes
Periodic breathing >= 10 minutes

1=unusual occurrences - periodic breathing > 5 minutes

Sleep Monitoring/Polysomnography/Signal Quality
plmou25
Periodic limb movement (PLM) > 25 verified (must be in sleep)
Periodic limb movement (PLM) > 25 verified (must be in sleep)

1=Outlier - Periodic limb movement (PLM) > 25 verified

Sleep Monitoring/Polysomnography/Signal Quality
processdt
Date data were processed
Date data were processed Sleep Monitoring/Polysomnography/Signal Quality
psndur
Hours of usable position
Hours of usable position

*All non-compumedics collected studies have position hand scored by scorer from notes supplied by site / none of position signals transfer in European Data Format (EDF) only numbers

Sleep Monitoring/Polysomnography/Signal Quality
pwfdur
Hours of usable pleth wave form
Hours of usable pleth wave form Sleep Monitoring/Polysomnography/Signal Quality
qsahi
Apnea-Hypopnea Index (AHI)
Apnea-Hypopnea Index (AHI)

Recorded by the scorer on QS form

Sleep Monitoring/Polysomnography/Signal Quality
qsoai
Obstructive apnea index (OAI)
Obstructive apnea index (OAI)

Recorded by the scorer on QS form

Sleep Monitoring/Polysomnography/Signal Quality
quabdo
Quality of abdominal effort
Quality of abdominal effort Sleep Monitoring/Polysomnography/Signal Quality
quair
Quality of airflow
Quality of airflow Sleep Monitoring/Polysomnography/Signal Quality
quc3
Quality of C3
Quality of C3

Quality of EEG

Sleep Monitoring/Polysomnography/Signal Quality
quc4
Quality of C4
Quality of C4

Quality of EEG

Sleep Monitoring/Polysomnography/Signal Quality
qucan
Quality of cannula
Quality of cannula Sleep Monitoring/Polysomnography/Signal Quality
quchest
Quality of chest effort
Quality of chest effort Sleep Monitoring/Polysomnography/Signal Quality
quchin
Quality of chin
Quality of chin Sleep Monitoring/Polysomnography/Signal Quality
queogl
Quality of EOG L
Quality of EOG L Sleep Monitoring/Polysomnography/Signal Quality
queogr
Quality of EOG R
Quality of EOG R Sleep Monitoring/Polysomnography/Signal Quality
quf3
Quality of F3
Quality of F3

Quality of EEG

Sleep Monitoring/Polysomnography/Signal Quality
quf4
Quality of F4
Quality of F4

Quality of EEG

Sleep Monitoring/Polysomnography/Signal Quality
quhr
Quality of hr
Quality of hr Sleep Monitoring/Polysomnography/Signal Quality
qulegl
Quality of LegL
Quality of LegL Sleep Monitoring/Polysomnography/Signal Quality
qulegr
Quality of LegR
Quality of LegR Sleep Monitoring/Polysomnography/Signal Quality
qum1
Quality of M1
Quality of M1

Quality of EEG

Sleep Monitoring/Polysomnography/Signal Quality
qum2
Quality of M2
Quality of M2

Quality of EEG

Sleep Monitoring/Polysomnography/Signal Quality
quo1
Quality of O1
Quality of O1

Quality of EEG

Sleep Monitoring/Polysomnography/Signal Quality
quo2
Quality of O2
Quality of O2

Quality of EEG

Sleep Monitoring/Polysomnography/Signal Quality
qupsn
Quality of position
Quality of position

*position for all non-compumedics data hand scored from notes from site tech

Sleep Monitoring/Polysomnography/Signal Quality
qupwf
Quality of pleth wave form
Quality of pleth wave form Sleep Monitoring/Polysomnography/Signal Quality
quref
Quality of reference
Quality of reference Sleep Monitoring/Polysomnography/Signal Quality
qusnor
Quality of snore
Quality of snore

Quality of snore microphone

Sleep Monitoring/Polysomnography/Signal Quality
qusum
Quality of SUM
Quality of SUM

Quality of SUM channel

Sleep Monitoring/Polysomnography/Signal Quality
qut3
Quality of T3
Quality of T3 Sleep Monitoring/Polysomnography/Signal Quality
qut4
Quality of T4
Quality of T4 Sleep Monitoring/Polysomnography/Signal Quality
rcvddt
Date received at reading center
Date received at reading center Sleep Monitoring/Polysomnography/Signal Quality
recbeaw
Data lost - recording ended before waking
Data lost - recording ended before waking

1=data Lost - recording ended before wake

Sleep Monitoring/Polysomnography/Signal Quality
remarunrel
Scoring arousals in rapid eye movement sleep (REM) (only) unreliable
Scoring arousals in rapid eye movement sleep (REM) (only) unreliable

1=arousals in rapid eye movement sleep (REM) unreliable (when EMG is artifactual or absent during all or rapid eye movement sleep (REM) portion of the study)

Sleep Monitoring/Polysomnography/Signal Quality
remnrempr
Scoring rapid eye movement sleep (REM)/non-rapid eye movement sleep (NREM) unreliable
Scoring rapid eye movement sleep (REM)/non-rapid eye movement sleep (NREM) unreliable

1=Sleep staging problem - scoring rapid eye movement sleep (REM)/non-rapid eye movement sleep (NREM) unreliable (when identification of Stage rapid eye movement sleep (REM) is unreliable (usually due to poor or missing EMG or when both EOGs are absent))

Sleep Monitoring/Polysomnography/Signal Quality
respevpr
Scoring respiratory events (Respiratory Disturbance Index (RDI)) unreliable
Scoring respiratory events (Respiratory Disturbance Index (RDI)) unreliable

1=Problems with respiratory events (when due to the technical quality of the respiratory signals, distinctions between hypopneas and normal breaths are equivocal in over 20 % of scored events; also when the quality of the oximetry signal raises doubts about actual magnitude of desaturation linked with over 20 % of respiratory events (unstable baseline)

Sleep Monitoring/Polysomnography/Signal Quality
reviewdt
Date of preliminary review
Date of preliminary review Sleep Monitoring/Polysomnography/Signal Quality
rsnco
Reason for study failure
Reason for study failure Sleep Monitoring/Polysomnography/Signal Quality
sa02lt90
Urgent referral - oxygen saturation (SaO2) <90% >2% sleep time = 1 urgent ineligible
Urgent referral - oxygen saturation (SaO2) <90% >2% sleep time = 1 urgent ineligible

*Note studies that have oximetry problems here

Sleep Monitoring/Polysomnography/Signal Quality
sa02lt92
Urgent referral - oxygen saturation (SaO2) <92% >2% sleep time = 1 Surgeon alert
Urgent referral - oxygen saturation (SaO2) <92% >2% sleep time = 1 Surgeon alert

*Note studies that have oximetry problems here

Sleep Monitoring/Polysomnography/Signal Quality
scordt
Date scored
Date scored

Date scoring performed at reading center

Sleep Monitoring/Polysomnography/Signal Quality
scoredt
Scored date
Scored date

Date scored (date of birth in compumedics screen) if study reprocessed date scored changes

Sleep Monitoring/Polysomnography/Signal Quality
scorid
Scorer ID
Scorer ID

ID of reading center staff who performed scoring

Sleep Monitoring/Polysomnography/Signal Quality
slewake
Study scored sleep wake = 1, all sleep scored stage 2
Study scored sleep wake = 1, all sleep scored stage 2

1=Study scored sleep wake

Sleep Monitoring/Polysomnography/Signal Quality
snordur
Hours of usable snore
Hours of usable snore Sleep Monitoring/Polysomnography/Signal Quality
staendt
Week ending date
Week ending date Sleep Monitoring/Polysomnography/Signal Quality
status
Pass fail status (passed=1 failed=2)
Pass fail status (passed=1 failed=2) Sleep Monitoring/Polysomnography/Signal Quality
stg1stg2pr
Scoring stage1/ stage 2 unreliable
Scoring stage1/ stage 2 unreliable

1=Sleep staging problem - scoring stage1/stage2 unreliable (when K-complexes and sleep spindles do not have show their classical morphology and distinction between Stage 1 and Stage 2 is doubtful (characteristic for the studies with low voltage EEG))

Sleep Monitoring/Polysomnography/Signal Quality
stg2stg3pr
Scoring stage2/ deep sleep unreliable
Scoring stage2/ deep sleep unreliable

1=sleep staging problem - scoring stage2/stage3-4 unreliable (when distinction between Stage 2 and Deep Sleep is unreliable because of EEG artifact (usually due to the respiratory or sweat artifact on the EEG, and High Pass filter =1Hz used))

Sleep Monitoring/Polysomnography/Signal Quality
sumdur
Hours of usable SUM
Hours of usable SUM Sleep Monitoring/Polysomnography/Signal Quality
t3dur
Hours of usable T3
Hours of usable T3

Hours of usable EEG

Sleep Monitoring/Polysomnography/Signal Quality
t4dur
Hours of usable T4
Hours of usable T4

Hours of usable EEG

Sleep Monitoring/Polysomnography/Signal Quality
unuhroth
Urgent - other heart rate arrhythmia, heart block, v-tach, etc. = 1 urgent ineligible
Urgent - other heart rate arrhythmia, heart block, v-tach, etc. = 1 urgent ineligible Sleep Monitoring/Polysomnography/Signal Quality
unuhrou
Urgent - problem heart rate < 40 bpm or > 140 bpm > 2 minutes = 1 urgent ineligible
Urgent - problem heart rate < 40 bpm or > 140 bpm > 2 minutes = 1 urgent ineligible

1=Medical alert for unusual heart rate or electrocardiogram (ECG)

Sleep Monitoring/Polysomnography/Signal Quality
unustgou
Extreme staging distribution
Extreme staging distribution

1=outlier - unusual staging

Sleep Monitoring/Polysomnography/Signal Quality
wakslepr
Scoring stage wake/sleep unreliable
Scoring stage wake/sleep unreliable

1=Sleep staging problem - scoring wake/sleep unreliable (when the clarity of the EEG makes distinguishing the transition unreliable)

Sleep Monitoring/Polysomnography/Signal Quality